The steps between 8A and 16A for a mobile charging cable are: 8A, 10A, 13A, and 16A. These are standard settings on adjustable mobile charging cables, such as those from Voldt, allowing you to adapt the charging power to the available power supply and location.
Why are these steps selected?
Each step (8A, 10A, 13A, 16A) corresponds to common circuit breaker levels and domestic grid standards across Europe. 8A is the most conservative option and is useful for older installations. 10A is a moderate step that fits most household sockets. 13A is common in the UK, where plugs are fused at 13A. The 16A setting offers the fastest charging rate where a dedicated circuit or heavy-duty socket is available.
Practical use of adjustable current levels
Adjustable charging cables like the Voldt Type 2 mobile charging cable allow manual or digital selection of current. This is essential when charging at locations with limited power or shared circuits. Lower current avoids tripping breakers, while 16A enables faster charging if the grid can handle it.
Safety and compatibility
Correct current settings are crucial for safe charging. Voldt cables include thermal sensors and overload protection, and they shut off automatically in unsafe conditions. Make sure the selected current matches your electrical system, and check if you're on a 1-phase or 3-phase setup. Some countries have different rules for 16A connections, so always verify local requirements.